Part Number Hot Search : 
FMS2016 LTC4099 G402SD 08HT58CP IRF730 R0800 SDS511 C10H1
Product Description
Full Text Search
 

To Download HAC300S Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  hitron electronics corporation. b4-11, p.o. box 26-110 kaohsiung export processing zone kaohsiung 806 taiwan tel: 886-7-8210410/fax: 886-7-8419917, 886-7-8210511/e-mail: sale s@hitron-e.com/web-site: www.hitron-e.com edited on march 13, 2013 -1- h hitron universal ac input harmonic correction ac-dc hot-swap compactpci serial single output with standby 312 watts active current sharing switching power supplies HAC300S series features: ? 312w 3u x 8hp eurocard package ? wide operating temperature range of -40c to +70 c ? meet iec 61000-3-2 harmonic correction ? n+1 redundancy/hot-swappable ? 80 plus gold efficiency ? active current sharing ? pmbus communication ? fully compliant with picmg specification input specification input voltage: typ. 90-264vac. power factor correction: meet harmonic correction iec 61000-3-2.power factor typ. 0.98-0.99. input connector: fci 51939-667lf. input frequency: 47-63hz. inrush current: 5.3arms at 230vac. input current: 3a at 115vac/1.5a at 230vac. dielectric withstand: meet iec 60950-1 regulation. emi: meet en 55022 / fcc class b. hold-up time: 18ms at 115 & 230vac. leakage current: less than 0.7ma at 230vac. power fail signal: available at [fal#] pin. remote on/off: available. status led: means valid input voltage. means a critical fault. means dc ok. thermal protection (otp): installed ntc and thermostat for thermal sensor at [deg#] pin. output specification output voltage: see ratings chart. output current: see ratings chart. output wattage: typ. 312w continuous. output connector: fci 51939-667lf. line regulation: typ. 1%. load regulation: vo1 typ. 1%./ standby typ. 5% noise & ripple: typ. 1% peak to peak. ovp: built-in at all outputs. adjustability: available for vo1. remote sensing: available for vo1. dc ok: available for vo1 & +5vsb. hot-swap: available. n+1 redundancy: installed with internal or-ing diodes at all outputs for n+1 redundancy operation. current sharing: active current sharing at vo1. overload protection (olp): fully protected against output overload or short circuit. olp set at 120-130% peak current at 115vac. consult the factory for special olp setting. general specification efficiency: typ. 90% at 230vac. switching frequency: 85-100k hz. circuit topology: llc circuit. transient response: peak transient less than 134mv and recovers within 0.5ms after 25% load-change. safety standard: iec 60950-1 class i. construction: 3u x 8hp compactpci format. front panel with extractor handle. operating temperature: -40 c to +70 c (see note 3) , derate linearly from 100% power at +50 c to 60% power at +70 c (refer to derating curve). storage temperature: -45 to +85 c. cooling: at least 200 lfm moving air is required to achieve full rating power 312w in a confined area. power density: 5.7 watts/ cubic inch. note: (1)all measurement are at nominal input, full load and +25c unless otherwise specifications. (2)due to requests in market and advances in technology , specifications subject to change without notification. (3)a warm-up time 10 minutes is required after co ld start at temperature from -40 c to +0c. (4)tantalum capacitors connected to system is suggested for bettering ripple & noise against operating temperature from -40c t o +0c.
hitron electronics corporation. b4-11, p.o. box 26-110 kaohsiung export processing zone kaohsiung 806 taiwan tel: 886-7-8210410/fax: 886-7-8419917, 886-7-8210511/e-mail: sale s@hitron-e.com/web-site: www.hitron-e.com edited on march 13, 2013 -2- output voltage / current ratings chart mechanical dimensions: mm [inches] weight: 710 g (25.1 oz.) quad output main vo1 @ standby vo2 model no. min. typ. volt. max. peak min. typ. volt. max. peak HAC300S-d120e 0a 25.0a 12v 25.0a 28.0a 0a 2.5a 5v 2.5a 3.0a symbol: " " ovp built-in. "@" adjustable . "#" remote sensing. " " active load sharing. ." " installed with or-ing diode. remark: 1.peak load less than 60s ec. with duty cycle <10%. 2.max. load is the continuous operating load of each rail. but the max. load of each rail can't be drawn from all outputs at th e same time. 3.please consult the factory if you have the special min load request of vo1. input & output connectors pin assignment p1 p2 p3 p4 p5 d1 d2 d3 d4 d5 d6 p6 p7 p8 p9 n/a fal ps_p com deg 5vsb c1 c2 c3 c4 c5 c6 n/a n/a com a0 alert 5vsb b1 b2 b3 b4 b5 b6 n/a 12vcs pson a1 scl com a1 a2 a3 a4 a5 a6 line neutral gnd n/a n.a n/a -vs +vs a2 sda en com com vo1 +12v vo1 +12v remark: mating connector fci 51940-350lf derating curve


▲Up To Search▲   

 
Price & Availability of HAC300S

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X